CRIS
Permanent URI for this communityhttps://investigadores.udd.cl/handle/123456789/1
Browse
787 results
Search Results
Now showing 1 - 10 of 787
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Barriers to access to insulin pumps in Chile: A qualitative study of a high-cost technology(Elsevier BV, 2025-03); ; ;Paula MadridDaniela Paredes2Scopus© Citations 2 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Cost-effectiveness of screening, decolonisation and isolation strategies for carbapenem-resistant Enterobacterales and methicillin-resistant Staphylococcus aureus infections in hospitals: a sex-stratified mathematical modelling study(Elsevier BV, 2025-03) ;Kasim Allel ;Patricia Garcia ;Anne Peters; Eduardo A. Undurraga2 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Adherence to an Early Exercise Plan Promotes Visceral Fat Loss in the First Month Following Bariatric Surgery(Springer Science and Business Media LLC, 2025-02-14) ;Johanna Pino-Zuñiga ;Paloma Lillo-Urzua ;Mariela Olivares-Galvez ;Ana Palacio-AgueroJuan Camilo Duque3Scopus© Citations 2 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Myocardial perfusion imaging in advanced coronary artery disease(Wiley, 2025-03-18) ;Roel Hoek ;Pepijn A. van Diemen ;Yvemarie B. O. Somsen ;Ruben W. de WinterRuurt A. JukemaMyocardial perfusion imaging (MPI) is widely adapted as a noninvasive technique to assess the presence and extent of ischemia in patients with symptoms suggestive of obstructive coronary artery disease (CAD). However, as CAD advances, several factors can complicate the interpretation of MPI, subsequently impacting clinical decision‐making. This review focuses on the utility of MPI by means of cardiac magnetic resonance (CMR) imaging, single‐photon emission computed tomography (SPECT) and positron emission tomography (PET) in patients with advanced CAD—the latter characterized by documented CAD (i.e. prior myocardial infarction [MI] and/or percutaneous coronary intervention [PCI]), prior coronary artery bypass grafting (CABG) or the presence of a chronic total occlusion (CTO). It will discuss factors impacting the interpretation of MPI, the diagnostic performance for detecting obstructive CAD and coronary microvascular dysfunction (CMD), as well as the role of MPI in guiding revascularization.Scopus© Citations 1 2 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Gut Microbiota‐Derived Extracellular Vesicles Influence Alcohol Intake Preferences in Rats(Wiley, 2025-03) ;Macarena Díaz‐Ubilla ;Aliosha I. Figueroa‐Valdés ;Hugo E. Tobar ;María Elena QuintanillaEugenio Díaz<jats:title>ABSTRACT</jats:title><jats:p>Growing preclinical and clinical evidence suggests a link between gut microbiota dysbiosis and problematic alcohol consumption. Extracellular vesicles (EVs) are key mediators involved in bacteria‐to‐host communication. However, their potential role in mediating addictive behaviour remains unexplored. This study investigates the role of gut microbiota‐derived bacterial extracellular vesicles (bEVs) in driving high alcohol consumption. bEVs were isolated from the gut microbiota of a high alcohol‐drinking rat strain (UChB rats), either ethanol‐naïve or following chronic alcohol consumption and administered intraperitoneally or orally to alcohol‐rejecting male and female Wistar rats. Both types of UChB‐derived bEVs increased Wistar's voluntary alcohol consumption (three bottle choice test) up to 10‐fold (<jats:italic>p</jats:italic> < 0.0001), indicating that bEVs are able and sufficient to transmit drinking behaviour across different rat strains. Molecular analysis revealed that bEVs administration did not induce systemic or brain inflammation in the recipient animals, suggesting that the increased alcohol intake triggered by UChB‐derived bEVs operates through an inflammation‐independent mechanism. Furthermore, we demonstrate that the vagus nerve mediates the bEV‐induced increase in alcohol consumption, as bilateral vagotomy completely abolished the high drinking behaviour induced by both intraperitoneally injected and orally administered bEVs. Thus, this study identifies bEVs as a novel mechanism underlying gut microbiota‐induced high alcohol intake in a vagus nerve‐dependent manner.</jats:p>7 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Risk and impact of stroke across 38 countries and territories of the Americas from 1990 to 2021: a population-based trends analysis from the Global Burden of Disease Study 2021(Elsevier BV, 2025-03) ;Ramón Martinez; ;Pedro Ordunez ;Felipe FregniCarlos AbantoScopus© Citations 22 3 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Intersectionality, racism, and mental health of migrants arriving at borders in Latin America: a qualitative study based on in-depth interviews with key informants of the cases of Ecuador and Chile(Elsevier BV, 2025-04) ;Teresita Rocha-Jiménez ;Irene Torres; ;Daniel F. López-CevallosMercedes Mercado-ÓrdenesScopus© Citations 1 1 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Emergency Department Workflow Times of Intravenous Thrombolysis with Tenecteplase versus Alteplase in Acute Ischemic Stroke: A Prospective Cohort Study before and during the COVID-19 Pandemic(S. Karger AG, 2025-02-03) ;Matias Guzman; ;Gabriel Cavada ;Alejandro M. BrunserVeronica V. OlavarriaIntroduction: Tenecteplase (TNK) has demonstrated to be non-inferior to alteplase (ALT) for intravenous thrombolysis (IVT) in acute ischemic stroke (AIS). There are potential workflow benefits associated with TNK use, aiming to reduce patient length of stay in the emergency department. Our aim was to investigate whether the routine use of TNK during the COVID-19 pandemic influenced workflow times compared to historical use of ALT, while maintaining non-inferior clinical outcomes in a non-drip and ship scenario of a comprehensive stroke center. Methods: We included patients with AIS admitted from September 2019 to September 2022 and compared those treated with TNK during the COVID-19 pandemic to those treated with ALT in the period immediately before. We compared emergency department length of stay (EDLOS), door-to-needle time (DTN), door-to-groin puncture time (DTG), clinical and safety outcomes with adjusted general linear regression models. Results: 110 patients treated with TNK and 111 with ALT were included in this study. Mean EDLOS was 251 (SD = 164) min for TNK users versus 240 (SD = 148) min for ALT (p = 0.62). Mean DTN was 43 (SD = 25) min for TNK versus 46 (SD = 27) min for ALT users (p = 0.39). Mean DTN under 60 min was achieved in 86 (78.2%) patients and in 85 (76.5%) patients of the TNK and ALT groups, respectively (p = 1.0). DTN under 45 min was achieved in 65.4% and 58.6% (p = 0.65) of the TNK and ALT groups, respectively. DTG time was 114 (SD = 43) min for TNK versus 111 (58 = SD) min in the ALT group (p = 0.88). DTG under 90 min was achieved in 32% of the TNK group and 35% of the ALT group (p = 0.69). There were no differences in any of the clinical or safety outcomes between groups at 90 days. Conclusions: The adoption of TNK during COVID-19 pandemic did not result in a change in EDLOS, DTN, or DTG times when compared to ALT in this cohort. Safety and clinical outcomes were similar between groups. Probably a greater benefit could have been seen in a drip and ship thrombolysis setting. Further research is needed to assess the potential advantages of TNK in drip and ship scenarios of IVT.Scopus© Citations 2 2 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Rethinking the Schenck Classification for Multiligament Knee Injuries: Evaluating Whether the Schenck KD Grade Is Associated With the Presence of Vascular or Neurological Injuries in a Multicenter Study With 144 Patients(SAGE Publications, 2025-03) ;Enrique Sanchez-Munoz ;Beatriz Lozano Hernanz ;Renato Andrade ;Cristina ValenteJoão Espregueira-MendesScopus© Citations 2 1 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Use of an Advanced Hybrid Closed Loop System During Marathon Running: Case Examples and Clinical Implications(Wiley, 2025-02-28) ;María T. Onetto ;Denise Montt‐Blanchard ;Cari Berget ;Kristel StrodhoffBruno GrassiMaintaining glucose levels in the target range during aerobic training and athletic competition is especially difficult. The use of Automated Insulin Delivery (AID) technology is increasing, but exercise continues to be a challenge for persons with type 1 diabetes (T1D). In this case report series, we present 3 cases (C1, C2 and C3) of persons with T1D who used the MiniMed 780G during marathon races. We describe the strategies they used before, during and after the race to manage their glycaemia as well as the results of these strategies on their glycaemic control during the race.</jats:p></jats:sec><jats:sec><jats:title>Methods</jats:title><jats:p>The Medtronic CareLink platform was employed to remotely access insulin pump settings and glycaemic outcomes. Race parameters were obtained from sport watches. Supplemental data were obtained through interviews.</jats:p></jats:sec><jats:sec><jats:title>Results</jats:title><jats:p>Carelink data for Cases 1, 2, and 3 before the race were downloaded: Time in range (TIR) 70–180 mg/dL 89%, 76%, 82%; time above range (TAR) > 180 mg/dL, 9%, 20%, 16%; time below range (TBR) < 70 mg/dL, 1%, 4%, 1%, respectively. The breakfast insulin reduction percentages were −25%, 0%, and 0% for C1, C2, and C3, respectively. In all three cases, insulin dose reduction was applied to the pre‐race snack at percentages of −50%, −100% and −83%. The consumption of carbohydrates during the race was 0.39 g/kg/hour, 0.42 g/kg/hour, and 0.5 g/kg/hour, respectively. The total amount of carbohydrates consumed was 101 g, 120 g, and 115 g, respectively. Throughout the race, a temporary target was used for all cases.</jats:p></jats:sec><jats:sec><jats:title>Conclusions</jats:title><jats:p>These cases provide insights for healthcare professionals who assist athletes with T1D using AID systems during prolonged physical activities. Highlighting the significance of specialised education, planning, and personalised approaches.</jats:p></jats:sec>4