Now showing 1 - 9 of 9
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Scopus© Citations 4  2
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Longitudinal assessment of SARS-CoV-2 IgG seroconversionamong front-line healthcare workers during the first wave of the Covid-19 pandemic at a tertiary-care hospital in Chile
    (2021) ;
    Macarena R. Vial
    ;
    Maria Spencer-Sandino
    ;
    Pablo Gaete
    ;
    Anne Peters
    <jats:title>Abstract</jats:title><jats:sec> <jats:title>Background</jats:title> <jats:p>Healthcare workers (HCWs) are at high risk of exposure to SARS-CoV-2. Cross-sectional studies have provided variable rates of seroprevalence in HCWs. Longitudinal assessments of the serological response to Covid-19 among HCWs are crucial to understanding the risk of infection and changes in antibody titers over time. We aimed to investigate seroprevalence and risk factors associated with seroconversion in a prospective cohort of HCWs during the peak of the first wave of the Covid-19 pandemic.</jats:p> </jats:sec><jats:sec> <jats:title>Methods</jats:title> <jats:p>We conducted a longitudinal study among 446 front-line HCWsin a tertiary-care hospital in Chile from April to July 2020. IgG was determined monthly using two different ELISAs in serum samples of HCWs, during the three-month period. In each visit, demographic data, symptoms, risk factors, and exposure risks were also assessed.</jats:p> </jats:sec><jats:sec> <jats:title>Results</jats:title> <jats:p>The overall seroprevalence at the end of the study period was 24% (95% CI20.2–28.3), with 43% of seropositive HCWs reporting no prior symptoms. Seroconversion rates significantly differed over the study period, from 2.1% to as high as 8.8% at the peak of the epidemic. There were no statistically significant differences observed between HCWs in direct clinical care of patients with Covid-19 and those working in low risk areas. Antibody titers appeared to wane over time.</jats:p> </jats:sec><jats:sec> <jats:title>Conclusions</jats:title> <jats:p>HCWs were severely affected with a high rate of seroconversion that appeared to mirror the local epidemiological situation. A significant amount of participants underwent an asymptomatic infection, highlighting the need for improved surveillance policies. Antibody titers appear to wane over time; further studies to understand this finding’s impact on the risk of reinfection are warranted.</jats:p> </jats:sec>
      1Scopus© Citations 21  2
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Campylobacter spp. Prevalence in Santiago, Chile: A Study Based on Molecular Detection in Clinical Stool Samples from 2014 to 2019
    (2023) ;
    Caricia Pérez
    ;
    Mario Barbé
    ;
    Carmen Varela
    ;
    Valeska Vollrath
    <jats:p>Campylobacter spp. is an emerging cause of infectious diarrhea worldwide. In South American countries such as Chile, its prevalence is underestimated due to inadequate detection methods. Gastrointestinal multiplex PCR panels (GMP) permit rapid and sensitive detection of bacterial pathogens and provide important epidemiological information. This study aimed to analyze Campylobacter epidemiology using the results of molecular methods and to compare molecular detection results to those of culture methods. We performed a retrospective, descriptive analysis of Campylobacter spp. detected in clinical stool samples between 2014–2019 by GMP and culture. Within 16,582 specimens examined by GMP, Campylobacter was the most prevalent enteropathogenic bacteria (8.5%), followed by Salmonella spp. (3.9%), Shigella spp./enteroinvasive Escherichia coli (EIEC) (1.9%), and Yersinia enterocolitica (0.8%). The highest Campylobacter prevalence occurred in 2014/2015. Campylobacteriosis affected more males (57.2%) and adults from 19–65 years (47.9%) and showed a bimodal seasonality with summer and winter peaks. In 11,251 routine stool cultures, Campylobacter spp. was detected in 4.6%, mostly C. jejuni (89.6%). Among 4533 samples tested by GMP and culture in parallel, GMP showed a superior sensitivity (99.1% versus 50%, respectively). The study suggests that Campylobacter spp. is the most frequent bacterial enteropathogen in Chile.</jats:p>
      1Scopus© Citations 6  1
  • Some of the metrics are blocked by your 
    Item type:Publication,
      42  1Scopus© Citations 46
  • Some of the metrics are blocked by your 
    Item type:Publication,
      6  1Scopus© Citations 6
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Performance of the VITEK® MS system for the identification of filamentous fungi in a microbiological laboratory in Chile
    (Public Library of Science (PLoS), 2024-12-23) ;
    Rodrigo Cruz
    ;
    Pérez Villa, Inia
    ;
    Carmen Varela
    ;
    Cristina DĂ­az
    <jats:p>Filamentous fungi are an emergent cause of severe infections in immunocompromised patients. Timely and accurate identification is crucial to initiate appropriate therapy. Traditional identification methods are time-consuming, labor-intensive, and operator-dependent. Matrix-assisted laser desorption/ionization-time-of-flight (MALDI-TOF) mass spectrometry is a rapid and easy-to-perform identification method. The effectiveness of a commercial MALDI-TOF MS platform to identify filamentous fungi in a clinical laboratory was evaluated. The study included 67 fungal isolates from 35 species/species complexes, which were identified and confirmed in mycology reference laboratories; 32 derived from clinical samples, 34 from strain collections and one was an ATCC strain. The study used the VITEK<jats:sup>®</jats:sup> MS system (v3.2.0 database), after sample extraction by VITEK<jats:sup>®</jats:sup> MS Mould Kit. Results were classified as “correct species”, “correct species complex”, “correct genus”and “no identification”. VITEK<jats:sup>®</jats:sup> MS correctly identified 91.0% of isolates (58.2% to species, 29.9% to species complex, and 1.5% to genus level only). In 82%, the result matched the species/species complex identified by reference methods. No misidentifications were observed. The kit was rapid and easy to use. In conclusion, the VITEK<jats:sup>®</jats:sup> MS system showed a high capability to accurately identify filamentous fungi in a clinical laboratory.</jats:p>
      1
  • Some of the metrics are blocked by your 
    Item type:Publication,
      15Scopus© Citations 278
  • Some of the metrics are blocked by your 
    Item type:Publication,
    A prospective, multi-center study of Candida bloodstream infections in Chile
    (2019)
    Maria E. Santolaya
    ;
    ;
    Dona Benadof
    ;
    Cecilia Tapia
    ;
    Claudia Cortés
      1Scopus© Citations 37  10
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Evaluation of two fluorescence immunoassays for the rapid detection of SARS-CoV-2 antigen—new tool to detect infective COVID-19 patients
    <jats:sec> <jats:title>Background</jats:title> <jats:p>Real-Time Reverse-Transcription Polymerase Chain Reaction (RT-PCR) is currently the only recommended diagnostic method for SARS-CoV-2. However, rapid immunoassays for SARS-CoV-2 antigen could significantly reduce the COVID-19 burden currently weighing on laboratories around the world.</jats:p> </jats:sec> <jats:sec> <jats:title>Methods</jats:title> <jats:p>We evaluated the performance of two rapid fluorescence immunoassays (FIAs), SOFIA SARS Antigen FIA (Quidel Corporation, San Diego, CA, USA) and STANDARD F COVID-19 Ag FIA (SD Biosensor Inc., Gyeonggi-do, Republic of Korea), which use an automated reader. The study used 64 RT-PCR characterized clinical samples (32 positive; 32 negative), which consisted of nasopharyngeal swabs in universal transport medium.</jats:p> </jats:sec> <jats:sec> <jats:title>Results</jats:title> <jats:p>Of the 32 positive specimens, all from patients within 5 days of symptom onset, the Quidel and SD Biosensor assays detected 30 (93.8%) and 29 (90.6%) samples, respectively. Among the 27 samples with high viral loads (Ct ≤ 25), the two tests had a sensitivity of 100%. Specificity was 96.9% for both kits.</jats:p> </jats:sec> <jats:sec> <jats:title>Conclusion</jats:title> <jats:p>The high performance of the evaluated FIAs indicates a potential use as rapid and PCR-independent tools for COVID-19 diagnosis in early stages of infection. The excellent sensitivity to detect cases with viral loads above ~10<jats:sup>6</jats:sup> copies/mL (Ct values ≤ 25), the estimated threshold of contagiousness, suggests that the assays might serve to rapidly identify infective individuals.</jats:p> </jats:sec>
      1Scopus© Citations 21