UDD Logo
CRIS - Current Research Information System
New user? Click here to register.Have you forgotten your password?
Communities & Collections
Research Outputs
Fundings & Projects
Researchers
Datasets
Statistics
  1. Home
  2. CRIS
  3. Publications
  4. Validity and Reliability of a New Radiological Method to Estimate Medial Column Internal Rotation in Hallux Valgus Using Foot Weight-Bearing X-Ray
Details

Validity and Reliability of a New Radiological Method to Estimate Medial Column Internal Rotation in Hallux Valgus Using Foot Weight-Bearing X-Ray

Journal
Foot & Ankle Specialist
ISSN
1938-6400
1938-7636
Date Issued
2021
Author(s)
WAGNER HITSCHFELD, PABLO  
Facultad de Medicina Clínica Alemana Universidad del Desarrollo  
Nicole Lescure
Noman Siddiqui
Jessica Fink
WAGNER, EMILIO  
Facultad de Medicina Clínica Alemana Universidad del Desarrollo  
Type
Resource Types::text::journal::journal article
Scopus ID
2-s2.0-85109817417
WoS ID
WOS:001179552300006
DOI
10.1177/19386400211029162
URL
https://investigadores.udd.cl/handle/123456789/6638
URL Institutional Repository
http://hdl.handle.net/11447/6062
Abstract
<jats:sec><jats:title>Background</jats:title><jats:p> Medial column internal rotation in hallux valgus (HV) can be measured using weight-bearing computed tomography (WBCT). Anteroposterior weight-bearing foot radiographs’ (WBXR) ability to estimate medial column internal rotation in HV was evaluated comparing these measurements with those obtained from WBCT. </jats:p></jats:sec><jats:sec><jats:title>Methods</jats:title><jats:p> Three observers evaluated WBCT and WBXR of 33 HV feet twice. Medial column internal rotation was measured with WBCT and classified into 3 levels according to WBXR findings. Intra- and interobserver reliability were obtained for WBXR and WBCT, in addition to WBXR-WBCT correlation. </jats:p></jats:sec><jats:sec><jats:title>Results</jats:title><jats:p> WBXR and WBCT intraobserver agreement was substantial and near perfect, respectively (κ 0.79 and 0.84). Their interobserver agreement was excellent (intraclass correlation 0.85 and 0.9, respectively). The WBXR-WBCT correlation was substantial (κ 0.68). WBXR diagnostic accuracy to predict the WBCT results was 85%. </jats:p></jats:sec><jats:sec><jats:title>Conclusions</jats:title><jats:p> The proposed method for medial column internal rotation measurement using WBXR is reliable and has a substantial agreement with WBCT measurements. </jats:p></jats:sec><jats:sec><jats:title>Levels of Evidence</jats:title><jats:p> Level III </jats:p></jats:sec>
Cite this document
Wagner, P., Lescure, N., Siddiqui, N., Fink, J., & Wagner, E. (2024). Validity and reliability of a new radiological method to estimate medial column internal rotation in hallux valgus using foot weight-bearing x-ray. Foot & Ankle Specialist, 17(1), 14-22. https://doi.org/10.1177/19386400211029162
Subjects
hallux valgus

; 

medial column pronation

; 

pronation classification

; 

bunion

; 

deformity

; 

weight-bearing ap view x-ray

; 

weight-bearing computer tomography

; 

bunion

; 

hallux valgus

; 

humans

; 

metatarsal bones

; 

reproducibility of results

; 

retrospective studies

; 

weight-bearing

; 

x-rays

; 

diagnostic imaging

; 

hallux valgus

; 

human

; 

metatarsal bone

; 

reproducibility

; 

retrospective study

; 

weight bearing

; 

x ray
Logo Universidad de Desarrollo
Encuéntranos en:

Sede Santiago

Av. Plaza 680, Las Condes

Contacto|Mapa

Sede Concepción

Ainavillo 456, Concepción

Contacto|Mapa

Hosting & SupportLogo Scimago Lab

Built with DSpace-CRIS software - Extension maintained and optimized by 4science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback
Repository logo COAR Notify