UDD Logo
CRIS - Current Research Information System
New user? Click here to register.Have you forgotten your password?
Communities & Collections
Research Outputs
Fundings & Projects
Researchers
Datasets
Statistics
  1. Home
  2. CRIS
  3. Publications
  4. Exogenous Volatile Organic Compound (EVOC®) Breath Testing Maximizes Classification Performance for Subjects with Cirrhosis and Reveals Signs of Portal Hypertension
Details

Exogenous Volatile Organic Compound (EVOC®) Breath Testing Maximizes Classification Performance for Subjects with Cirrhosis and Reveals Signs of Portal Hypertension

Journal
Biomedicines
ISSN
2227-9059
Date Issued
2023
Author(s)
Giuseppe Ferrandino
Federico Ricciardi
Antonio Murgia
Iris Banda
Menisha Manhota
Yusuf Ahmed
Kelly Sweeney
Louise Nicholson-Scott
Lucinda McConville
Olga Gandelman
Max Allsworth
Billy Boyle
Agnieszka Smolinska
Carmen A. Ginesta Frings
Facultad de Medicina Clínica Alemana Universidad del Desarrollo  
Jorge Contreras
Claudia Asenjo-Lobos  
Viviana Barrientos
Nataly Clavo
Angela Novoa
Amy Riviotta
Melissa Jerez
Luis Méndez
Type
Resource Types::text::journal::journal article
Scopus ID
2-s2.0-85178353378
WoS ID
WOS:001109525300001
DOI
10.3390/biomedicines11112957
URL
https://investigadores.udd.cl/handle/123456789/8403
URL Institutional Repository
https://repositorio.udd.cl/handle/11447/8311
Abstract
<jats:p>Background: Cirrhosis detection in primary care relies on low-performing biomarkers. Consequently, up to 75% of subjects with cirrhosis receive their first diagnosis with decompensation when causal treatments are less effective at preserving liver function. We investigated an unprecedented approach to cirrhosis detection based on dynamic breath testing. Methods: We enrolled 29 subjects with cirrhosis (Child–Pugh A and B), and 29 controls. All subjects fasted overnight. Breath samples were taken using Breath Biopsy® before and at different time points after the administration of 100 mg limonene. Absolute limonene breath levels were measured using gas chromatography–mass spectrometry. Results: All subjects showed a >100-fold limonene spike in breath after administration compared to baseline. Limonene breath kinetics showed first-order decay in >90% of the participants, with higher bioavailability in the cirrhosis group. At the Youden index, baseline limonene levels showed classification performance with an area under the roc curve (AUROC) of 0.83 ± 0.012, sensitivity of 0.66 ± 0.09, and specificity of 0.83 ± 0.07. The best performing timepoint post-administration was 60 min, with an AUROC of 0.91, sensitivity of 0.83 ± 0.07, and specificity of 0.9 ± 0.06. In the cirrhosis group, limonene bioavailability showed a correlation with MELD and fibrosis indicators, and was associated with signs of portal hypertension. Conclusions: Dynamic limonene breath testing enhances diagnostic performance for cirrhosis compared to static testing. The correlation with disease severity suggests potential for monitoring therapeutic interventions. Given the non-invasive nature of breath collection, a dynamic limonene breath test could be implemented in primary care.</jats:p>
Cite this document
Ferrandino, G., Ricciardi, F., Murgia, A., Banda, I., Manhota, M., Ahmed, Y., Sweeney, K., Nicholson-Scott, L., McConville, L., Gandelman, O., Allsworth, M., Boyle, B., Smolinska, A., Ginesta Frings, C. A., Contreras, J., Asenjo-Lobos, C., Barrientos, V., Clavo, N., Novoa, A., … Méndez, L. (2023). Exogenous volatile organic compound (Evoc®) breath testing maximizes classification performance for subjects with cirrhosis and reveals signs of portal hypertension. Biomedicines, 11(11), 2957. https://doi.org/10.3390/biomedicines11112957
Subjects
breath biopsy

; 

functional diagnostics

; 

meld

; 

non-invasive

; 

volatile organic compounds
Logo Universidad de Desarrollo
Encuéntranos en:

Sede Santiago

Av. Plaza 680, Las Condes

Contacto|Mapa

Sede Concepción

Ainavillo 456, Concepción

Contacto|Mapa

Hosting & SupportLogo Scimago Lab

Built with DSpace-CRIS software - Extension maintained and optimized by 4science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback
Repository logo COAR Notify