CRIS

Permanent URI for this communityhttps://investigadores.udd.cl/handle/123456789/1

Browse

Search Results

Now showing 1 - 5 of 5
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Scopus© Citations 4  3
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Diagnosis and classification of optic neuritis
    (2022)
    Axel Petzold
    ;
    Clare L Fraser
    ;
    Mathias Abegg
    ;
    Raed Alroughani
    ;
    Daniah Alshowaeir
    Scopus© Citations 81  2
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Venous Air Microembolism in Chest CT Angiography: Evidence of Normalization of Deviance Phenomenon
    <jats:title>Abstract</jats:title><jats:p> Purpose This article provides evidence that detection of venous air microbubbles (VAMB) in chest computed tomography angiography (CTA) can be an indicator for “normalization of deviance” phenomenon in CT.</jats:p><jats:p> Method and Materials Institutional review board-approved retrospective study, with waiver for informed consent. Contrast-enhanced chest CT performed during 6 months were reviewed for presence of VAMB in venous segments visible in chest CT (subclavian, brachiocephalic vein, superior vena cava) and cardiac chambers. VAMB volumes were quantified through a semiautomatic method (MIAlite plugin for OsiriX), using a region of interest (ROI) covering the bubble. With basal results, protocols for correct injection technique were reinforced, and VAMB were estimated again at 1 and 3 months. Six months later, questionnaires were sent to the CT technologists to inquire about their perception of VAMB. Descriptive measures with central distribution and dispersion were performed; statistical significance was considered at p &lt; 0.05.</jats:p><jats:p> Results A total of 602 chest CTA were analyzed, 332 were women (55.14%), with a median age of 58 (interquartile range [IQR] 44–72) years. Among those, 16.11% (100 cases) presented VAMB. Most were emergency department patients (51.6%), male (50.3%), with a median age of 54 (IQR 26) years. There was no difference on detection of VAMB regarding sex (p = 0.19), age (p = 0.46), or referral diagnosis (p = 0.35). Mean air bubbles volume was 0.2 mL (range 0.01–3.4 mL). After intervention, the number of exams with VAMB dropped to 3.29 % (3/91) (p &lt; 0.001). On the 6-month query, 50% of the technicians still considered that VMAB is inevitable, and 60% thought that the occurrence is not associated to risk, and therefore, not actionable.</jats:p><jats:p> Conclusion VAMB are a frequent finding in chest CTA, and being independent from patient-related variables, it is likely due to technical issues such as intravenous access manipulation during the exam. Reduction after reinforcement of proper performance, and certification of a low concern from CT technicians for any risk associated, provides evidence that there is normalization of deviance in this everyday procedure.</jats:p>
      14Scopus© Citations 2
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Virtual Unenhanced Images at Dual-Energy CT: Influence on Renal Lesion Characterization
    (2019)
    Mathias Meyer
    ;
    Rendon C. Nelson
    ;
    Federica Vernuccio
    ;
    ;
    Alfredo E. Farjat
      1Scopus© Citations 66
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Scopus© Citations 16  1