  4. Study of the Suitability of a Personal Exposure Monitor to Assess Air Quality
Details

Study of the Suitability of a Personal Exposure Monitor to Assess Air Quality

Journal
Atmosphere
ISSN
2073-4433
Date Issued
2024
Author(s)
Halah E. Aljofi
Thomas J. Bannan
Michael Flynn
James Evans
David Topping
Emily Matthews
DIEZ, SEBASTIÁN CESAR  
Facultad de Ingeniería  
Pete Edwards
Hugh Coe
Daniel R. Brison
Martie van Tongeren
Edward D. Johnstone
Andrew Povey
Type
journal-article
Scopus ID
2-s2.0-85188823646
WoS ID
WOS:001191931800001
DOI
10.3390/atmos15030315
URL
https://investigadores.udd.cl/handle/123456789/9991
Abstract
<jats:p>Low-cost personal exposure monitors (PEMs) to measure personal exposure to air pollution are potentially promising tools for health research. However, their adoption requires robust validation. This study evaluated the performance of twenty-one Plume Lab Flow2s (PLFs) by comparing its air pollutant measurements, particulate matter with a diameter of 2.5 μm or less (PM2.5), 10 μm or less (PM10), and nitrogen dioxide (NO2), against several high-quality air pollution monitors under field conditions (at indoor, outdoor, and roadside locations). Correlation and regression analysis were used to evaluate measurements obtained by different PLFs against reference instrumentation. For all measured pollutants, the overall correlation coefficient between the PLFs and the reference instruments was often weak (r < 0.4). Moderate correlation was observed for one PLF unit at the indoor location and two units at the roadside location when measuring PM2.5, but not for PM10 and NO2 concentration. During periods of particularly higher pollution, 11 PLF tools showed stronger regression results (R2 values > 0.5) with one-hour and 9 PLF units with one-minute time interval. Results show that the PLF cannot be used robustly to determine high and low exposure to poor air. Therefore, the use of PLFs in research studies should be approached with caution if data quality is important to the research outputs.</jats:p>
Cite this document
Aljofi, H. E., Bannan, T. J., Flynn, M., Evans, J., Topping, D., Matthews, E., Diez, S., Edwards, P., Coe, H., Brison, D. R., Van Tongeren, M., Johnstone, E. D., & Povey, A. (2024). Study of the suitability of a personal exposure monitor to assess air quality. Atmosphere, 15(3), 315. https://doi.org/10.3390/atmos15030315
Subjects
personal monitoring tools

; 

air pollution monitoring

; 

air quality monitoring

; 

commercial portable low-cost wearable sensor

; 

portable air quality

; 

field evaluation

; 

public health

; 

performance evaluation
Logo Universidad de Desarrollo
Encuéntranos en:

Sede Santiago

Av. Plaza 680, Las Condes

Contacto|Mapa

Sede Concepción

Ainavillo 456, Concepción

Contacto|Mapa

Hosting & SupportLogo Scimago Lab

Built with DSpace-CRIS software - Extension maintained and optimized by 4science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback
Repository logo COAR Notify